SCOPE OF WORK: This specification includes waterproofing to wet area like bathrooms, kitchen, toilet, balconies, planter and laundry area etc.,
MATERIALS: The waterproofing materials shall be liquid applied or torch applied membrane. Liquid applied system shall be polyurethane or SBS bitumen base single component. Highly durable liquid waterproofing membrane with good elasticity. Which cures to a tough rubber like finish with tenacious adhesion.
SUBSTRATE: The waterproofing system shall be installed over dry, smooth and clean concrete floors. It shall be smooth plastered using SBS concrete additive. A sand cement mortar angle fillet shall be formed at the corner and around pipe penetrations such for smooth termination of the membrane
Apply a full coat concrete primer prepared surface and minimum 50mm above finished floor level on the plastered wall. If liquid applied membrane is specified, the substrate shall be prepared and liquid applied coating shall be brush applied at the rate 1.5kg/m2